{"id":1144,"date":"2018-08-23T10:15:06","date_gmt":"2018-08-23T10:15:06","guid":{"rendered":"http:\/\/priorclavena.com\/?p=1144"},"modified":"2020-11-03T20:18:49","modified_gmt":"2020-11-03T20:18:49","slug":"research-lab-autoclave-safety-bad-doors-and-autoclave-explosions","status":"publish","type":"post","link":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/","title":{"rendered":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions"},"content":{"rendered":"<p>&nbsp;<\/p>\n<p class=\"p1\"><b><i>WARNING<\/i><\/b>: These are disturbing pictures of research lab autoclave accidents. There is blood.<\/p>\n<p class=\"p1\"><i>What happened?<\/i><span class=\"Apple-converted-space\">\u00a0 <\/span>A lab tech loaded an older-style autoclave, began the cycle, and walked away to attend to other tasks.<span class=\"Apple-converted-space\">\u00a0 <\/span>Either due to user error or wear-and-tear over time, the door locking mechanism was not fully engaged.<span class=\"Apple-converted-space\">\u00a0 <\/span>As the cycle progressed, the chamber pressure climbed.<span class=\"Apple-converted-space\">\u00a0 <\/span>Mid-cycle the pressure peaked, blowing the door off the autoclave.<span class=\"Apple-converted-space\">\u00a0 <\/span>It struck the worker, who was 50 feet away at the time, resulting in serious injuries.<\/p>\n<p class=\"p1\">Note that while the person involved in this incident was only injured, autoclave doors have been responsible for several fatalities.<span class=\"Apple-converted-space\">\u00a0 <\/span>Even when everything operates normally and the autoclave is in good repair, older models can be opened prematurely.<span class=\"Apple-converted-space\">\u00a0 <\/span>The force of the door flying open&#8211;even if the hinges hold&#8211;can strike a worker with tremendous force.<\/p>\n<div id=\"attachment_1149\" style=\"width: 310px\" class=\"wp-caption alignleft\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1149\" class=\"alignnone size-full wp-image-1194\" src=\"http:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explosion-counter-300x223-1.png\" alt=\"autoclave explosion detail, blood\" width=\"300\" height=\"223\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explosion-counter-300x223-1.png 300w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explosion-counter-300x223-1-64x48.png 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explosion-counter-300x223-1-128x95.png 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explosion-counter-300x223-1-240x178.png 240w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-1149\" class=\"wp-caption-text\">(source: Colorado State University Biosafety Office)<\/p><\/div>\n<p class=\"p1\">(Incidentally, this sort of explosion <i>cannot<\/i> happen with a modern autoclave equipped with <a href=\"http:\/\/www.priorclave.com\/en-us\/why-priorclave\/quality-reliability-safety\/\">computer-controlled permission-based door release and mechanical thermal\/pressure interlocks<\/a>.)<\/p>\n<h2 class=\"p1\">A Cheap Dental Autoclave is a Ticking Bomb<\/h2>\n<p class=\"p1\">A similar <a href=\"https:\/\/www.netdentista.com\/autoclaves-e-compressores\/\">autoclave explosion in a Brazilian dental clinic<\/a>\u00a0(here\\&#8217;s the article <a href=\"https:\/\/translate.google.com\/translate?hl=en&amp;sl=pt&amp;tl=en&amp;u=https%3A%2F%2Fwww.netdentista.com%2Fautoclaves-e-compressores%2F\">Google Translated from the Portuguese<\/a>).<\/p>\n<div id=\"attachment_1148\" style=\"width: 310px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1148\" class=\"alignnone size-full wp-image-1195\" src=\"http:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-1-300x169-1.jpg\" alt=\"Brazil dental autoclave explosion (interior)\" width=\"300\" height=\"169\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-1-300x169-1.jpg 300w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-1-300x169-1-64x36.jpg 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-1-300x169-1-128x72.jpg 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-1-300x169-1-240x135.jpg 240w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><p id=\"caption-attachment-1148\" class=\"wp-caption-text\">interior (<a href=\"https:\/\/www.netdentista.com\/autoclaves-e-compressores\/\">source<\/a>)<\/p><\/div>\n<p class=\"p1\">This incident resulted in no injuries (the autoclave room was empty at the time), but massive structural damage:<\/p>\n<div id=\"attachment_1145\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1145\" class=\"alignnone size-full wp-image-1196\" src=\"http:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1.jpg\" alt=\"Brazil dental autoclave explosion (exterior)\" width=\"640\" height=\"360\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1.jpg 640w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-300x169.jpg 300w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-64x36.jpg 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-128x72.jpg 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-240x135.jpg 240w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-320x180.jpg 320w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-360x203.jpg 360w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-375x211.jpg 375w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-480x270.jpg 480w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/compressor-explodiu-2-1-540x304.jpg 540w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/><p id=\"caption-attachment-1145\" class=\"wp-caption-text\">exterior of building (<a href=\"https:\/\/www.netdentista.com\/autoclaves-e-compressores\/\">source<\/a>)<\/p><\/div>\n<p class=\"p1\">In this case, the failure was attributed to metal fatigue.<span class=\"Apple-converted-space\">\u00a0 <\/span>According to the<span class=\"Apple-converted-space\">\u00a0 <\/span>manufacturer, doors should be replaced every five years(!) as a matter of &#8220;routine maintenance&#8221;(!!!)<\/p>\n<div id=\"attachment_1146\" style=\"width: 550px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1146\" class=\"alignnone size-full wp-image-1197\" src=\"http:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1.jpg\" alt=\"Brazil dental autoclave explosion (door detail)\" width=\"540\" height=\"960\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1.jpg 540w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-169x300.jpg 169w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-64x114.jpg 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-128x228.jpg 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-240x427.jpg 240w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-320x569.jpg 320w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-360x640.jpg 360w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-375x667.jpg 375w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/autoclave-explode-2-1-480x853.jpg 480w\" sizes=\"auto, (max-width: 540px) 100vw, 540px\" \/><p id=\"caption-attachment-1146\" class=\"wp-caption-text\">detail of damaged autoclave door (<a href=\"https:\/\/www.netdentista.com\/autoclaves-e-compressores\/\">source<\/a>)<\/p><\/div>\n<p class=\"p1\">Yet another reason we are highly, <a href=\"http:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/Tabletop-Autoclaves-Priced-to-Sell-Not-Built-to-Last.pdf\">highly suspicious of second-hand and dental autoclaves in research settings<\/a>.<\/p>\n<h2 class=\"p1\">Research Lab Autoclave Safety Best Practices<\/h2>\n<p class=\"p1\">While dramatic, explosions like these are rare.<span class=\"Apple-converted-space\">\u00a0 <\/span>The real danger when operating the autoclave is also the absolutely most mundane thing about it: <b>The heat<\/b>.<span class=\"Apple-converted-space\">\u00a0 <\/span>Steam autoclaves are effective <i>because<\/i> steam transfers heat so well, better than air and most lab surfaces.<span class=\"Apple-converted-space\">\u00a0 <\/span>And that steam does not differentiate between red bags and your arms.<span class=\"Apple-converted-space\">\u00a0 <\/span>Stay safe:<\/p>\n<ul class=\"ul1\">\n<li class=\"li1\">Always wear appropriate PPE<\/li>\n<li class=\"li1\">Don\\\\&#8217;t open the autoclave door until pressure has dropped to 0 psi<\/li>\n<li class=\"li1\">Wait 10 minutes with the door cracked open before removing any materials from the autoclave<\/li>\n<li class=\"li1\">Step to the side when opening the autoclave; keep your face and body clear of the door and any exiting steam<\/li>\n<li class=\"li1\">Never autoclave a tightly capped bottle<\/li>\n<li class=\"li1\">Always check to make sure the door is firmly closed<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; WARNING: These are disturbing pictures of research lab autoclave accidents. There is blood. What happened?\u00a0 A lab tech loaded an older-style autoclave, began the cycle, and walked away to [&hellip;]<\/p>\n","protected":false},"author":15,"featured_media":3012,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[73],"tags":[323,324,325,68,31],"class_list":["post-1144","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-lab-autoclaves","tag-autoclave-injury","tag-autoclave-safety","tag-explosions","tag-lab-safety","tag-safety"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions\" \/>\n<meta property=\"og:description\" content=\"&nbsp; WARNING: These are disturbing pictures of research lab autoclave accidents. There is blood. What happened?\u00a0 A lab tech loaded an older-style autoclave, began the cycle, and walked away to [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/\" \/>\n<meta property=\"og:site_name\" content=\"Priorclave - United States\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-23T10:15:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-11-03T20:18:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"552\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Priorclave North America\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Priorclave North America\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/\"},\"author\":{\"name\":\"Priorclave North America\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/a12db1016486ac2f1829e04de99b4dc1\"},\"headline\":\"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions\",\"datePublished\":\"2018-08-23T10:15:06+00:00\",\"dateModified\":\"2020-11-03T20:18:49+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/\"},\"wordCount\":432,\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/explosion-fit-2.jpg\",\"keywords\":[\"autoclave injury\",\"autoclave safety\",\"explosions\",\"lab safety\",\"safety\"],\"articleSection\":[\"Lab Autoclaves\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/\",\"name\":\"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/explosion-fit-2.jpg\",\"datePublished\":\"2018-08-23T10:15:06+00:00\",\"dateModified\":\"2020-11-03T20:18:49+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/a12db1016486ac2f1829e04de99b4dc1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/explosion-fit-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/explosion-fit-2.jpg\",\"width\":640,\"height\":552},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/08\\\/23\\\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\",\"name\":\"Priorclave - United States\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/a12db1016486ac2f1829e04de99b4dc1\",\"name\":\"Priorclave North America\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g\",\"caption\":\"Priorclave North America\"},\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/author\\\/priorclavena1\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/","og_locale":"en_US","og_type":"article","og_title":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions","og_description":"&nbsp; WARNING: These are disturbing pictures of research lab autoclave accidents. There is blood. What happened?\u00a0 A lab tech loaded an older-style autoclave, began the cycle, and walked away to [&hellip;]","og_url":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/","og_site_name":"Priorclave - United States","article_published_time":"2018-08-23T10:15:06+00:00","article_modified_time":"2020-11-03T20:18:49+00:00","og_image":[{"width":640,"height":552,"url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg","type":"image\/jpeg"}],"author":"Priorclave North America","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Priorclave North America","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#article","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/"},"author":{"name":"Priorclave North America","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/a12db1016486ac2f1829e04de99b4dc1"},"headline":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions","datePublished":"2018-08-23T10:15:06+00:00","dateModified":"2020-11-03T20:18:49+00:00","mainEntityOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/"},"wordCount":432,"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg","keywords":["autoclave injury","autoclave safety","explosions","lab safety","safety"],"articleSection":["Lab Autoclaves"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/","url":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/","name":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#primaryimage"},"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg","datePublished":"2018-08-23T10:15:06+00:00","dateModified":"2020-11-03T20:18:49+00:00","author":{"@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/a12db1016486ac2f1829e04de99b4dc1"},"breadcrumb":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#primaryimage","url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg","contentUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/explosion-fit-2.jpg","width":640,"height":552},{"@type":"BreadcrumbList","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/08\/23\/research-lab-autoclave-safety-bad-doors-and-autoclave-explosions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.priorclave.com\/en-us\/"},{"@type":"ListItem","position":2,"name":"Research Lab Autoclave Safety: Bad Doors and Autoclave Explosions"}]},{"@type":"WebSite","@id":"https:\/\/www.priorclave.com\/en-us\/#website","url":"https:\/\/www.priorclave.com\/en-us\/","name":"Priorclave - United States","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.priorclave.com\/en-us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/a12db1016486ac2f1829e04de99b4dc1","name":"Priorclave North America","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7ce0c3ec6f3db9a46e29b6e7c034a1c7ed16de42245a5f50d28a14b085dfc422?s=96&d=mm&r=g","caption":"Priorclave North America"},"url":"https:\/\/www.priorclave.com\/en-us\/author\/priorclavena1\/"}]}},"_links":{"self":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/1144","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/users\/15"}],"replies":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/comments?post=1144"}],"version-history":[{"count":0,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/1144\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media\/3012"}],"wp:attachment":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media?parent=1144"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/categories?post=1144"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/tags?post=1144"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}