{"id":2825,"date":"2018-11-01T10:09:31","date_gmt":"2018-11-01T10:09:31","guid":{"rendered":"http:\/\/priorclavena.com\/?p=1168"},"modified":"2025-03-11T16:23:42","modified_gmt":"2025-03-11T16:23:42","slug":"autoclave-procedure-four-rules-for-no-mess-liquid-sterilization","status":"publish","type":"post","link":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/","title":{"rendered":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization"},"content":{"rendered":"<p class=\"p1\">As we&#8217;ve discussed before, the best autoclave procedure for running\u00a0<a href=\"https:\/\/www.priorclave.com\/en-us\/liquids-sterilizers-autoclaves\/\">liquid loads<\/a> is trickier\u00a0than just loading up the autoclave and choosing the &#8220;<a href=\"https:\/\/www.priorclave.com\/en-us\/2018\/10\/04\/research-lab-autoclave-best-practices-the-liquid-cycle-wont-save-you\/\">liquid cycle<\/a>.&#8221; Follow these four rules and you&#8217;ll largely avoid trashing your autoclave chamber, plumbing, and drain while losing your liquids to evaporation, boil over, or burst bottles:<\/p>\n<h2><b>1. Never fill the bottles more than half way<\/b><\/h2>\n<p>With containers bigger than 1L, you can <i>consider<\/i> going over 50%, but never do so for LB agar, and think twice before reducing the headspace when processing other agars, broths, or growth media.<span class=\"Apple-converted-space\">\u00a0 <\/span><i>Never, ever, <\/i><b><i>ever<\/i><\/b> fill any container more than 75%; always assume you&#8217;ll get at least ~20% boil up.<\/p>\n<h2><b>2. Always use a tray!<\/b><\/h2>\n<p><b>\u00a0<\/b>Some days you will mess up, or the barometric pressure will be especially high, or the autoclave vent will stick, or there will be a power surge, or \u2026 whatever. It&#8217;s very easy to dump out and rinse a tray, and very, very hard to clean an autoclave&#8217;s internal plumbing.<\/p>\n<h2><b>3. Always put at least .25&#8243; of water in that tray<\/b><\/h2>\n<p>Water absorbs and releases heat more slowly than air or steam; having your bottles rest in a water bath acts as a buffer and smooths out your temperature and pressure ramps.<span class=\"Apple-converted-space\">\u00a0 <\/span><b><i>Added bonus<\/i><\/b>: If a flask does overflow or burst, media diluted in a water bath cleans up very easily.<\/p>\n<h2><b>4. Best autoclave procedure: Assume the worst <i>will<\/i> happen<\/b><\/h2>\n<p>Run every load with the assumption that every bottle will, somehow, both boil over <i>and<\/i> burst:<span class=\"Apple-converted-space\">\u00a0 <\/span>Make sure your tray is deep enough to accommodate the water bath, all of the liquid from all of the flasks, and all of the broken glass without overflowing.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>As we&#8217;ve discussed before, the best autoclave procedure for running\u00a0liquid loads is trickier\u00a0than just loading up the autoclave and choosing the &#8220;liquid cycle.&#8221; Follow these four rules and you&#8217;ll largely [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":1317,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[25,180,73],"tags":[357,358,72,355,74,68,322,315,316],"class_list":["post-2825","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-benchtop-autoclaves","category-front-loading-autoclaves","category-lab-autoclaves","tag-autoclave-procedure","tag-autoclaving-liquids","tag-autoclaving-tips","tag-best-practices","tag-lab-practices","tag-lab-safety","tag-liquid-cycles","tag-liquid-loads","tag-liquid-sterilization"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization\" \/>\n<meta property=\"og:description\" content=\"As we&#8217;ve discussed before, the best autoclave procedure for running\u00a0liquid loads is trickier\u00a0than just loading up the autoclave and choosing the &#8220;liquid cycle.&#8221; Follow these four rules and you&#8217;ll largely [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/\" \/>\n<meta property=\"og:site_name\" content=\"Priorclave - United States\" \/>\n<meta property=\"article:published_time\" content=\"2018-11-01T10:09:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-11T16:23:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"426\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Priorclave North America\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Priorclave North America\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/\"},\"author\":{\"name\":\"Priorclave North America\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/b8dfc14748013f9601f785dff4dc7d7e\"},\"headline\":\"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization\",\"datePublished\":\"2018-11-01T10:09:31+00:00\",\"dateModified\":\"2025-03-11T16:23:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/\"},\"wordCount\":285,\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/interdisciplinary-lab-1.jpg\",\"keywords\":[\"autoclave procedure\",\"autoclaving liquids\",\"autoclaving tips\",\"best practices\",\"lab practices\",\"lab safety\",\"liquid cycles\",\"liquid loads\",\"liquid sterilization\"],\"articleSection\":[\"Benchtop Autoclaves\",\"Front Loading Autoclaves\",\"Lab Autoclaves\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/\",\"name\":\"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/interdisciplinary-lab-1.jpg\",\"datePublished\":\"2018-11-01T10:09:31+00:00\",\"dateModified\":\"2025-03-11T16:23:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/b8dfc14748013f9601f785dff4dc7d7e\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/interdisciplinary-lab-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/interdisciplinary-lab-1.jpg\",\"width\":640,\"height\":426,\"caption\":\"photo of a researcher at work\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2018\\\/11\\\/01\\\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\",\"name\":\"Priorclave - United States\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/b8dfc14748013f9601f785dff4dc7d7e\",\"name\":\"Priorclave North America\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"caption\":\"Priorclave North America\"},\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/author\\\/dnelson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/","og_locale":"en_US","og_type":"article","og_title":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization","og_description":"As we&#8217;ve discussed before, the best autoclave procedure for running\u00a0liquid loads is trickier\u00a0than just loading up the autoclave and choosing the &#8220;liquid cycle.&#8221; Follow these four rules and you&#8217;ll largely [&hellip;]","og_url":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/","og_site_name":"Priorclave - United States","article_published_time":"2018-11-01T10:09:31+00:00","article_modified_time":"2025-03-11T16:23:42+00:00","og_image":[{"width":640,"height":426,"url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg","type":"image\/jpeg"}],"author":"Priorclave North America","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Priorclave North America","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#article","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/"},"author":{"name":"Priorclave North America","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/b8dfc14748013f9601f785dff4dc7d7e"},"headline":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization","datePublished":"2018-11-01T10:09:31+00:00","dateModified":"2025-03-11T16:23:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/"},"wordCount":285,"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg","keywords":["autoclave procedure","autoclaving liquids","autoclaving tips","best practices","lab practices","lab safety","liquid cycles","liquid loads","liquid sterilization"],"articleSection":["Benchtop Autoclaves","Front Loading Autoclaves","Lab Autoclaves"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/","url":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/","name":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#primaryimage"},"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg","datePublished":"2018-11-01T10:09:31+00:00","dateModified":"2025-03-11T16:23:42+00:00","author":{"@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/b8dfc14748013f9601f785dff4dc7d7e"},"breadcrumb":{"@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#primaryimage","url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg","contentUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/08\/interdisciplinary-lab-1.jpg","width":640,"height":426,"caption":"photo of a researcher at work"},{"@type":"BreadcrumbList","@id":"https:\/\/www.priorclave.com\/en-us\/2018\/11\/01\/autoclave-procedure-four-rules-for-no-mess-liquid-sterilization\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.priorclave.com\/en-us\/"},{"@type":"ListItem","position":2,"name":"Autoclave Procedure: Four Rules for No-Mess Liquid Sterilization"}]},{"@type":"WebSite","@id":"https:\/\/www.priorclave.com\/en-us\/#website","url":"https:\/\/www.priorclave.com\/en-us\/","name":"Priorclave - United States","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.priorclave.com\/en-us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/b8dfc14748013f9601f785dff4dc7d7e","name":"Priorclave North America","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","caption":"Priorclave North America"},"url":"https:\/\/www.priorclave.com\/en-us\/author\/dnelson\/"}]}},"_links":{"self":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/2825","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/comments?post=2825"}],"version-history":[{"count":0,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/2825\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media\/1317"}],"wp:attachment":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media?parent=2825"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/categories?post=2825"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/tags?post=2825"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}