{"id":3159,"date":"2021-11-12T13:06:11","date_gmt":"2021-11-12T13:06:11","guid":{"rendered":"https:\/\/www.priorclave.com\/en-us\/?p=3159"},"modified":"2021-10-29T13:25:57","modified_gmt":"2021-10-29T13:25:57","slug":"3159","status":"publish","type":"post","link":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/","title":{"rendered":"Your Autoclave\u2019s HVAC Impact"},"content":{"rendered":"<p><span style=\"font-weight: 400\">An autoclave can have a major impact on your building&#8217;s heating, ventilation, and air conditioning (HVAC) system and indoor air quality. Occasionally, it&#8217;s a catastrophic impact. That was the case with this improperly vented steam autoclave<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2842 size-full\" src=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375.jpeg\" alt=\"HVAC damage Cleveland State University vent\" width=\"480\" height=\"640\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375.jpeg 480w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-225x300.jpeg 225w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-64x85.jpeg 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-128x171.jpeg 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-240x320.jpeg 240w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-320x427.jpeg 320w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-360x480.jpeg 360w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0375-375x500.jpeg 375w\" sizes=\"auto, (max-width: 480px) 100vw, 480px\" \/><\/p>\n<p><span style=\"font-weight: 400\">(One of our installers came across this heartbreak at a Midwestern American university back in 2014.)<\/span><\/p>\n<p><span style=\"font-weight: 400\">Even when there isn\u2019t a critical failure like this, an inefficient autoclave will always disproportionately contribute to <em>building loads<\/em>. That strains your HVAC system.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">With a little math and a few specs from the manufacturer website, you can quickly compare the baseline load an autoclave will put on your HVAC system. This can save for from a decade stuck with a steamy monster making your lab into a sauna.<\/span><\/p>\n<h2><span style=\"font-weight: 400\">Why Watch HVAC Load?<\/span><\/h2>\n<p><span style=\"font-weight: 400\">First and foremost, an overloaded HVAC system is going to mean uncomfortable building occupants and high energy bills.\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">Every steam autoclave is, essentially, a hot damp box. You&#8217;re going to need a heftier HVAC or ventilation system. Without having some sense of the HVAC load of your autoclave, it&#8217;s going to be hard to properly scale that HVAC system.\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">Those committed to &#8220;green&#8221; building practices and LEED building design principles take note.\u00a0 Efficient HVAC engineering is richly rewarded under LEED. Reducing the HVAC load also makes it easier to earn points in the Indoor Environmental Quality &#8220;Thermal Comfort&#8221; credits. That&#8217;s because these credits focus on the control, design, and verification of HVAC systems. If your HVAC system doesn&#8217;t have to fight a jacketed autoclave&#8217;s external steam generator, it&#8217;s going to be easier for occupants to meaningfully control the workspace.\u00a0<\/span><\/p>\n<h2><span style=\"font-weight: 400\">How to Calculate Your\u00a0 HVAC Load<\/span><\/h2>\n<p><span style=\"font-weight: 400\">HVAC load is a result of the autoclave&#8217;s &#8220;heat emission&#8221; (measured in kilowatts per hour). You can readily calculate this prior to purchase. In general, the thermal load placed on your HVAC by an autoclave is approximately one third of the total heater power for the unit\u2019s first hour of operation.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">To calculate an autoclave&#8217;s heat emission (when started from cold), use the following formula:<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-3160 aligncenter\" src=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-300x115.png\" alt=\"formula for calculating autoclave heat emissions \" width=\"300\" height=\"115\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-300x115.png 300w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-64x25.png 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-128x49.png 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-240x92.png 240w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-320x123.png 320w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-360x139.png 360w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-375x144.png 375w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-480x185.png 480w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1-540x208.png 540w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PriorclaveHeatEmissionFormula-1.png 577w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><span style=\"font-weight: 400\">Where:\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">Y = heat emission kW\/hour<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">X = the in-chamber heater&#8217;s power rating in kW<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">h = heat-up time in hours<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">p = process time in hours<\/span><\/li>\n<li style=\"font-weight: 400\"><span style=\"font-weight: 400\">t = total cycle (i.e., until the thermal lock releases and the door may be opened) in hours<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><span style=\"font-weight: 400\">Bear in mind that the output from the autoclave varies throughout the cycle. Nonetheless, this figure is a good guide for a thermal load calculation. (If you\u2019re using house steam, you can look up the wattage of the corresponding electrically heated autoclave. A calculation based on that wattage will give a good approximation of the thermal load.)<\/span><\/p>\n<p><span style=\"font-weight: 400\">For Priorclave autoclaves, you can rely on the following chart for the values to plug into your calculation. For other manufacturers\u2019 models, look for the data sheets on their website before starting your calculations.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3161 size-large\" src=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1024x778.png\" alt=\"Priorclave Autoclave Heating and Steam Generation Capacities\" width=\"1024\" height=\"778\" srcset=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1024x778.png 1024w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-300x228.png 300w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-768x583.png 768w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1536x1167.png 1536w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-2048x1556.png 2048w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-64x49.png 64w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-128x97.png 128w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-240x182.png 240w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-320x243.png 320w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-360x273.png 360w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-375x285.png 375w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-480x365.png 480w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-540x410.png 540w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-640x486.png 640w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-720x547.png 720w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-800x608.png 800w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-960x729.png 960w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1280x972.png 1280w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1366x1038.png 1366w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1600x1215.png 1600w, https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2021\/10\/PNA-Heat_Emmision_and_Steam_Ratings-2-1920x1458.png 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><span style=\"font-weight: 400\">It bears noting that the calculated heat emission for any autoclave is always proportional to the power rating for its heating element (listed in the second column of the chart).\u00a0\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">Many aspects of Priorclave\u2019s autoclave design (such as cold idling and in-chamber heating) significantly mitigate thermal impact because they allow us to use much smaller heating elements with the same results.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400\">(Cold idling also benefits the LEED conscious lab owner, as occasional\u2014rather than 24\/7\u2014operation both reduces the heat load in the lab and paves the way for several of the credits within the &#8220;Indoor Environmental Quality&#8221; category.)<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>An autoclave can have a major impact on your building&#8217;s heating, ventilation, and air conditioning (HVAC) system and indoor air quality. Occasionally, it&#8217;s a catastrophic impact. That was the case [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":2843,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[320],"tags":[361,480,110,220,381,80],"class_list":["post-3159","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-lab-design","tag-autoclave-tips","tag-building-load","tag-hvac","tag-lab-design","tag-thermal-load","tag-tips-and-tricks"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Your Autoclave\u2019s HVAC Impact<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Your Autoclave\u2019s HVAC Impact\" \/>\n<meta property=\"og:description\" content=\"An autoclave can have a major impact on your building&#8217;s heating, ventilation, and air conditioning (HVAC) system and indoor air quality. Occasionally, it&#8217;s a catastrophic impact. That was the case [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/\" \/>\n<meta property=\"og:site_name\" content=\"Priorclave - United States\" \/>\n<meta property=\"article:published_time\" content=\"2021-11-12T13:06:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"640\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Priorclave North America\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Priorclave North America\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/\"},\"author\":{\"name\":\"Priorclave North America\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/8b31c12dd95522a519b919985d6ce760\"},\"headline\":\"Your Autoclave\u2019s HVAC Impact\",\"datePublished\":\"2021-11-12T13:06:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/\"},\"wordCount\":587,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/12\\\/IMG_0377.jpeg\",\"keywords\":[\"autoclave tips\",\"building load\",\"HVAC\",\"lab design\",\"thermal load\",\"tips and tricks\"],\"articleSection\":[\"Lab Design\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/\",\"name\":\"Your Autoclave\u2019s HVAC Impact\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/12\\\/IMG_0377.jpeg\",\"datePublished\":\"2021-11-12T13:06:11+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/8b31c12dd95522a519b919985d6ce760\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/12\\\/IMG_0377.jpeg\",\"contentUrl\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/12\\\/IMG_0377.jpeg\",\"width\":480,\"height\":640,\"caption\":\"Building damage due to poor autoclave installation\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/2021\\\/11\\\/12\\\/3159\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Your Autoclave\u2019s HVAC Impact\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#website\",\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/\",\"name\":\"Priorclave - United States\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/#\\\/schema\\\/person\\\/8b31c12dd95522a519b919985d6ce760\",\"name\":\"Priorclave North America\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g\",\"caption\":\"Priorclave North America\"},\"url\":\"https:\\\/\\\/www.priorclave.com\\\/en-us\\\/author\\\/dnelson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Your Autoclave\u2019s HVAC Impact","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/","og_locale":"en_US","og_type":"article","og_title":"Your Autoclave\u2019s HVAC Impact","og_description":"An autoclave can have a major impact on your building&#8217;s heating, ventilation, and air conditioning (HVAC) system and indoor air quality. Occasionally, it&#8217;s a catastrophic impact. That was the case [&hellip;]","og_url":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/","og_site_name":"Priorclave - United States","article_published_time":"2021-11-12T13:06:11+00:00","og_image":[{"width":480,"height":640,"url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg","type":"image\/jpeg"}],"author":"Priorclave North America","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Priorclave North America","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#article","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/"},"author":{"name":"Priorclave North America","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/8b31c12dd95522a519b919985d6ce760"},"headline":"Your Autoclave\u2019s HVAC Impact","datePublished":"2021-11-12T13:06:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/"},"wordCount":587,"commentCount":0,"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg","keywords":["autoclave tips","building load","HVAC","lab design","thermal load","tips and tricks"],"articleSection":["Lab Design"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/","url":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/","name":"Your Autoclave\u2019s HVAC Impact","isPartOf":{"@id":"https:\/\/www.priorclave.com\/en-us\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#primaryimage"},"image":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#primaryimage"},"thumbnailUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg","datePublished":"2021-11-12T13:06:11+00:00","author":{"@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/8b31c12dd95522a519b919985d6ce760"},"breadcrumb":{"@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#primaryimage","url":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg","contentUrl":"https:\/\/www.priorclave.com\/en-us\/wp-content\/uploads\/sites\/3\/2018\/12\/IMG_0377.jpeg","width":480,"height":640,"caption":"Building damage due to poor autoclave installation"},{"@type":"BreadcrumbList","@id":"https:\/\/www.priorclave.com\/en-us\/2021\/11\/12\/3159\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.priorclave.com\/en-us\/"},{"@type":"ListItem","position":2,"name":"Your Autoclave\u2019s HVAC Impact"}]},{"@type":"WebSite","@id":"https:\/\/www.priorclave.com\/en-us\/#website","url":"https:\/\/www.priorclave.com\/en-us\/","name":"Priorclave - United States","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.priorclave.com\/en-us\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.priorclave.com\/en-us\/#\/schema\/person\/8b31c12dd95522a519b919985d6ce760","name":"Priorclave North America","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ddd164285c295da8fea40f7681fa8d17154184cce1ab962d04b0178d94f9e445?s=96&d=mm&r=g","caption":"Priorclave North America"},"url":"https:\/\/www.priorclave.com\/en-us\/author\/dnelson\/"}]}},"_links":{"self":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/3159","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/comments?post=3159"}],"version-history":[{"count":0,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/posts\/3159\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media\/2843"}],"wp:attachment":[{"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/media?parent=3159"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/categories?post=3159"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.priorclave.com\/en-us\/wp-json\/wp\/v2\/tags?post=3159"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}